Area of application:
Typical applications of the mag-flux F5 flow meter are measuring very small quantities and metering chemicals and pharmaceuticals.
The magnetic-inductive sensor is used in the following industries:
- Plant and mechanical engineering
- Chemicals
- Laboratory and medical technology
- Food
- Water and wastewater
Advantages of the magnetic-inductive flow meter for measuring very small quantities:
- Reliability (long-term stability, service life)
- Minimal maintenance requirements
- Simple commissioning
- High measurement accuracy
- Flexible installation position (however the measuring tube must be completely full at all times)
- Manufacturer’s application expertise
- Short lead times
Special features of the flow meter:
- Measuring tube made of highly corrosion and temperature-resistant zirconium oxide
- Measuring tube internal diameter from 2 mm (0.078")
- Robust and interference-free thanks to sealed steel casing
Very low measuring ranges:
- 0 to 5 l/h (0 to 0.022 USgpm) for d.c. measurement
- 0 to 3 l/h (0 to 0.0132 USgpm) for a.c. measurement
Very low minimum conductivity:
- 10 μS/cm for d.c. measurement
- 0.1 μS/cm for a.c. measurement
Various process connections:
- Threads: DIN, NPT, BSP
- Flange: DIN, ANSI, JIS
- Clamp
- DIN 11851
- Others on request
Various process connections materials:
- M. No. 1.4571
- Hastelloy C4 M. No. 2.4610
- PVDF with in Hastelloy C4 M. No. 2.4610 earthing ring
- Titanium
- Others on request
Operating principle |
pulsed constant field (DC) |
Measuring accuracy¹ |
error of measurement: ±0,4 % ±1 mm/s of MV repeatability: ± 0,15 % of MV |
Liquids |
min. conductivity: 20 μS/cm
min. flow velocity: 0.25 m/s (0.82 ft/s)
max. flow velocity: 10 m/s (32.8 ft/s) |
Temperature limits² |
process connection - metal: 0 °C to +150 °C
process connection - +120 °C / 3 bar; +50 °C / 10 bar |
Tube materials |
zirconium oxide |
Electrodes materials |
platinium 99,9 %, sintered |
Process connections |
Thread: DIN, NPT, BSP
Flange: ANSI B 16.5
(Tri-) Camp/DIN 11851
others on request
Materials:
Stainless Steel Mat.No. 1.4571,
Hastelloy® C4, PVDF, titanium
|
Manual
Declaration of conformity
- Calibration
- Service deployment (on-site inspection / maintenance)
- Repair
- Customer consulting by phone
- Extended warranty (on request if required)